This is a by design limit of the RAS SDK. Only work-around; place the subreport into a different section(s).

 

As a by the by, stuffing so many subreports into one report does have consequences that you may not want...

 

For one, if the detail section returns 100 records, each subreport is run by the report engine consuming a print job. You will quickly run out of print jobs as these are set at 75 by default. E.g.; with 40 subreports, you will be running 4001 report jobs (40subrpt *100recs + 1 main rpt). You can increase this limit, but at the expense of higher stresses on the hardware.

 

The performance of these reports will be very poor.

 

 